{"id":1765,"date":"2025-12-11T16:04:00","date_gmt":"2025-12-11T10:34:00","guid":{"rendered":"https:\/\/www.servokon.com\/blog\/?p=1765"},"modified":"2025-12-11T16:06:18","modified_gmt":"2025-12-11T10:36:18","slug":"11-essential-power-transformer-testing-methods-and-standards","status":"publish","type":"post","link":"https:\/\/www.servokon.com\/blog\/11-essential-power-transformer-testing-methods-and-standards\/","title":{"rendered":"11 Essential Power Transformer Testing Methods and Standards"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"1765\" class=\"elementor elementor-1765\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-c65c013 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"c65c013\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-bde0527\" data-id=\"bde0527\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-90aa914 elementor-widget elementor-widget-text-editor\" data-id=\"90aa914\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"color: #000000;\">Whether it is the conventional power generation plant or the renewable energy farms, the power transformers are crucial in every electrical power network. Their function is to step up the voltage so that the power transmission is feasible over long distances. It is a complex assembly of windings, insulation, terminals, bushings, relays and a temperature gauge. Each part should function well for the whole transformer to give reliable performance. Therefore, a series of tests based on international and national standards needs to be done on them.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-722f45c elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"722f45c\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-452dd22\" data-id=\"452dd22\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d98100f elementor-widget elementor-widget-heading\" data-id=\"d98100f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Essential Power Transformer Tests<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-9a0bd66 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"9a0bd66\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-c2c9d10\" data-id=\"c2c9d10\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ada89f5 elementor-widget elementor-widget-text-editor\" data-id=\"ada89f5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2><span style=\"color: #000000;\">1. Turns Ratio Test<\/span><\/h2><p><span style=\"color: #000000;\">The turns ratio is the relationship between the primary winding and the secondary winding. In this test, the rated value is matched with the measured ratio. If there is a deviation between the values, it indicates an incorrect connection or shorted turns.<\/span><\/p><h2><span style=\"color: #000000;\">2. Winding Resistance Test<\/span><\/h2><p><span style=\"color: #000000;\">This test is done to measure the direct current resistance of each winding. Tracking resistance indicates the ageing of the winding. If there is uneven reading, engineers look for loose joints, poor soldering or damaged conductors.<\/span><\/p><h2><span style=\"color: #000000;\">3. Load Loss and Impedance Test<\/span><\/h2><p><span style=\"color: #000000;\">Load losses and impedance value are measured at rated current. These indicate the copper losses and stray load losses when current flows through windings and how the transformer will act during faults. Accurate impedance is essential especially when multiple transformers are running in parallel.<\/span><\/p><h2><span style=\"color: #000000;\">4.\u00a0\u00a0\u00a0 Vector Group Verification<\/span><\/h2><p><span style=\"color: #000000;\">Vector group is the connection method of each winding and the phase displacement. It is verified to ensure that the transformer is connected properly to the grid. The mismatch can lead to an unwanted shift in phase and wrong relay operation.<\/span><\/p><h2><span style=\"color: #000000;\">5. Oil Quality and Dissolved Gas Analysis<\/span><\/h2><p><span style=\"color: #000000;\">Transformer oil is known for its insulation and for dissipating heat from the windings. In an oil quality test, the dielectric strength, moisture content, and acidity are measured, while the dissolved gas analysis tests the gases generated by internal heating, arcing or insulation decomposition. It is done regularly to monitor the health of the transformer.<\/span><\/p><h2><span style=\"color: #000000;\">6. No Load Loss<\/span><\/h2><p><span style=\"color: #000000;\">No load losses are hysteresis and eddy current loss. Excess value of these losses is a sign of a problem with core material, lamination and mechanical stress in the core. In the test, teh rated voltage is applied and input power is measured.<\/span><\/p><h2><span style=\"color: #000000;\">7. Dielectric Tests<\/span><\/h2><p><span style=\"color: #000000;\">Dielectric strength is the main property of the insulation system. To perform this test, a high voltage is applied to the windings between phases and earth. These tests are vital for transformer safety as they check that insulation clearances, solid insulation, oil and internal arrangements can withstand expected operating stresses.<\/span><\/p><h2><span style=\"color: #000000;\">8. Partial Discharge Measurement<\/span><\/h2><p><span style=\"color: #000000;\">Partial discharge is the electrical activity happening in the weak insulation, which can lead to failure. Sensitive instruments identify the particle discharge during type testing and diagnostic investigations to check insulation quality.<\/span><\/p><h2><span style=\"color: #000000;\">9. Short Circuit Withstand Test<\/span><\/h2><p><span style=\"color: #000000;\">These tests are conducted to verify that the transformer to withstand the mechanical stress caused by electrical faults. This is a test that demands high engineering skill and is mostly performed on a power transformer.<\/span><\/p><h2><span style=\"color: #000000;\">10. Impulse Test<\/span><\/h2><p><span style=\"color: #000000;\">This test is a simulation of lightning surges and overvoltages. If any irregularity is detected, it signifies a weakness in insulation or voltage distribution in the winding. It is done to ensure the ability of the transformer to withstand severe external disturbances.<\/span><\/p><h2><span style=\"color: #000000;\">11. Insulation Resistance Test<\/span><\/h2><p><span style=\"color: #000000;\">It measures resistance between windings and earth. This test is performed during commissioning and repeated throughout the course of the transformer&#8217;s life because when insulation deteriorates, there is a high risk of transformer failure.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-7aaad6c elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"7aaad6c\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-a69db22\" data-id=\"a69db22\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-e5c7e03 elementor-widget elementor-widget-heading\" data-id=\"e5c7e03\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conclusion<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-643b58c elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"643b58c\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-3100eb6\" data-id=\"3100eb6\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-f867e23 elementor-widget elementor-widget-text-editor\" data-id=\"f867e23\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"color: #000000;\">To check the performance of the power transformer under the given environmental conditions, electrical loads and mechanical forces, the above-mentioned tests are essentially done. It assures teh quality of the component, safety and long-term performance under IEC and relevant IS guidelines. If you want to know more about transformer testing and consult with a company for these tests, reach out to <strong>Servokon. <\/strong>Our comprehensive ability to manufacture and commission has made us a reliable expert on every aspect of transformers.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Whether it is the conventional power generation plant or the renewable energy farms, the power transformers are crucial in every electrical power network. Their function<\/p>\n","protected":false},"author":1,"featured_media":1766,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-1765","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.1.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>11 Essential Power Transformer Testing Methods and Standards | Servokon<\/title>\n<meta name=\"description\" content=\"Choose our Power transformer testing service to make sure best performance and safety of your equipment. Contact us today!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.servokon.com\/blog\/11-essential-power-transformer-testing-methods-and-standards\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"11 Essential Power Transformer Testing Methods and Standards | Servokon\" \/>\n<meta property=\"og:description\" content=\"Choose our Power transformer testing service to make sure best performance and safety of your equipment. Contact us today!\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.servokon.com\/blog\/11-essential-power-transformer-testing-methods-and-standards\/\" \/>\n<meta property=\"og:site_name\" content=\"Servokon System Ltd.\" \/>\n<meta property=\"article:published_time\" content=\"2025-12-11T10:34:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-11T10:36:18+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.servokon.com\/blog\/wp-content\/uploads\/2025\/12\/WhatsApp-Image-2025-12-11-at-15.49.34.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"1600\" \/>\n\t<meta property=\"og:image:height\" content=\"733\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"servo\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"servo\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.servokon.com\/blog\/11-essential-power-transformer-testing-methods-and-standards\/\",\"url\":\"https:\/\/www.servokon.com\/blog\/11-essential-power-transformer-testing-methods-and-standards\/\",\"name\":\"11 Essential Power Transformer Testing Methods and Standards | Servokon\",\"isPartOf\":{\"@id\":\"https:\/\/www.servokon.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.servokon.com\/blog\/11-essential-power-transformer-testing-methods-and-standards\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.servokon.com\/blog\/11-essential-power-transformer-testing-methods-and-standards\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.servokon.com\/blog\/wp-content\/uploads\/2025\/12\/WhatsApp-Image-2025-12-11-at-15.49.34.jpeg\",\"datePublished\":\"2025-12-11T10:34:00+00:00\",\"dateModified\":\"2025-12-11T10:36:18+00:00\",\"author\":{\"@id\":\"https:\/\/www.servokon.com\/blog\/#\/schema\/person\/c228dca4c16f0aa93387c00e48d77f61\"},\"description\":\"Choose our Power transformer testing service to make sure best performance and safety of your equipment. Contact us today!\",\"breadcrumb\":{\"@id\":\"https:\/\/www.servokon.com\/blog\/11-essential-power-transformer-testing-methods-and-standards\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.servokon.com\/blog\/11-essential-power-transformer-testing-methods-and-standards\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.servokon.com\/blog\/11-essential-power-transformer-testing-methods-and-standards\/#primaryimage\",\"url\":\"https:\/\/www.servokon.com\/blog\/wp-content\/uploads\/2025\/12\/WhatsApp-Image-2025-12-11-at-15.49.34.jpeg\",\"contentUrl\":\"https:\/\/www.servokon.com\/blog\/wp-content\/uploads\/2025\/12\/WhatsApp-Image-2025-12-11-at-15.49.34.jpeg\",\"width\":1600,\"height\":733,\"caption\":\"11 Essential Power Transformer Testing Methods and Standards\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.servokon.com\/blog\/11-essential-power-transformer-testing-methods-and-standards\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.servokon.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"11 Essential Power Transformer Testing Methods and Standards\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.servokon.com\/blog\/#website\",\"url\":\"https:\/\/www.servokon.com\/blog\/\",\"name\":\"Servokon System Ltd.\",\"description\":\"Rakhe Sab Control Mein\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.servokon.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.servokon.com\/blog\/#\/schema\/person\/c228dca4c16f0aa93387c00e48d77f61\",\"name\":\"servo\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.servokon.com\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/d1d64f49a2d92fec591b0ca25003ddeb4208347a13f1b4acf1b635f16f3a3a3d?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/d1d64f49a2d92fec591b0ca25003ddeb4208347a13f1b4acf1b635f16f3a3a3d?s=96&d=mm&r=g\",\"caption\":\"servo\"},\"sameAs\":[\"https:\/\/www.servokon.com\/blog\"],\"url\":\"https:\/\/www.servokon.com\/blog\/author\/servo\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"11 Essential Power Transformer Testing Methods and Standards | Servokon","description":"Choose our Power transformer testing service to make sure best performance and safety of your equipment. Contact us today!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.servokon.com\/blog\/11-essential-power-transformer-testing-methods-and-standards\/","og_locale":"en_US","og_type":"article","og_title":"11 Essential Power Transformer Testing Methods and Standards | Servokon","og_description":"Choose our Power transformer testing service to make sure best performance and safety of your equipment. Contact us today!","og_url":"https:\/\/www.servokon.com\/blog\/11-essential-power-transformer-testing-methods-and-standards\/","og_site_name":"Servokon System Ltd.","article_published_time":"2025-12-11T10:34:00+00:00","article_modified_time":"2025-12-11T10:36:18+00:00","og_image":[{"width":1600,"height":733,"url":"https:\/\/www.servokon.com\/blog\/wp-content\/uploads\/2025\/12\/WhatsApp-Image-2025-12-11-at-15.49.34.jpeg","type":"image\/jpeg"}],"author":"servo","twitter_card":"summary_large_image","twitter_misc":{"Written by":"servo","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.servokon.com\/blog\/11-essential-power-transformer-testing-methods-and-standards\/","url":"https:\/\/www.servokon.com\/blog\/11-essential-power-transformer-testing-methods-and-standards\/","name":"11 Essential Power Transformer Testing Methods and Standards | Servokon","isPartOf":{"@id":"https:\/\/www.servokon.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.servokon.com\/blog\/11-essential-power-transformer-testing-methods-and-standards\/#primaryimage"},"image":{"@id":"https:\/\/www.servokon.com\/blog\/11-essential-power-transformer-testing-methods-and-standards\/#primaryimage"},"thumbnailUrl":"https:\/\/www.servokon.com\/blog\/wp-content\/uploads\/2025\/12\/WhatsApp-Image-2025-12-11-at-15.49.34.jpeg","datePublished":"2025-12-11T10:34:00+00:00","dateModified":"2025-12-11T10:36:18+00:00","author":{"@id":"https:\/\/www.servokon.com\/blog\/#\/schema\/person\/c228dca4c16f0aa93387c00e48d77f61"},"description":"Choose our Power transformer testing service to make sure best performance and safety of your equipment. Contact us today!","breadcrumb":{"@id":"https:\/\/www.servokon.com\/blog\/11-essential-power-transformer-testing-methods-and-standards\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.servokon.com\/blog\/11-essential-power-transformer-testing-methods-and-standards\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.servokon.com\/blog\/11-essential-power-transformer-testing-methods-and-standards\/#primaryimage","url":"https:\/\/www.servokon.com\/blog\/wp-content\/uploads\/2025\/12\/WhatsApp-Image-2025-12-11-at-15.49.34.jpeg","contentUrl":"https:\/\/www.servokon.com\/blog\/wp-content\/uploads\/2025\/12\/WhatsApp-Image-2025-12-11-at-15.49.34.jpeg","width":1600,"height":733,"caption":"11 Essential Power Transformer Testing Methods and Standards"},{"@type":"BreadcrumbList","@id":"https:\/\/www.servokon.com\/blog\/11-essential-power-transformer-testing-methods-and-standards\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.servokon.com\/blog\/"},{"@type":"ListItem","position":2,"name":"11 Essential Power Transformer Testing Methods and Standards"}]},{"@type":"WebSite","@id":"https:\/\/www.servokon.com\/blog\/#website","url":"https:\/\/www.servokon.com\/blog\/","name":"Servokon System Ltd.","description":"Rakhe Sab Control Mein","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.servokon.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.servokon.com\/blog\/#\/schema\/person\/c228dca4c16f0aa93387c00e48d77f61","name":"servo","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.servokon.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/d1d64f49a2d92fec591b0ca25003ddeb4208347a13f1b4acf1b635f16f3a3a3d?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d1d64f49a2d92fec591b0ca25003ddeb4208347a13f1b4acf1b635f16f3a3a3d?s=96&d=mm&r=g","caption":"servo"},"sameAs":["https:\/\/www.servokon.com\/blog"],"url":"https:\/\/www.servokon.com\/blog\/author\/servo\/"}]}},"_links":{"self":[{"href":"https:\/\/www.servokon.com\/blog\/wp-json\/wp\/v2\/posts\/1765","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.servokon.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.servokon.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.servokon.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.servokon.com\/blog\/wp-json\/wp\/v2\/comments?post=1765"}],"version-history":[{"count":4,"href":"https:\/\/www.servokon.com\/blog\/wp-json\/wp\/v2\/posts\/1765\/revisions"}],"predecessor-version":[{"id":1770,"href":"https:\/\/www.servokon.com\/blog\/wp-json\/wp\/v2\/posts\/1765\/revisions\/1770"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.servokon.com\/blog\/wp-json\/wp\/v2\/media\/1766"}],"wp:attachment":[{"href":"https:\/\/www.servokon.com\/blog\/wp-json\/wp\/v2\/media?parent=1765"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.servokon.com\/blog\/wp-json\/wp\/v2\/categories?post=1765"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.servokon.com\/blog\/wp-json\/wp\/v2\/tags?post=1765"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}