{"id":1910,"date":"2026-07-15T12:57:00","date_gmt":"2026-07-15T07:27:00","guid":{"rendered":"https:\/\/www.servokon.com\/blog\/?p=1910"},"modified":"2026-08-01T13:00:36","modified_gmt":"2026-08-01T07:30:36","slug":"isolation-transformers-understanding-their-purposes-and-functions","status":"publish","type":"post","link":"https:\/\/www.servokon.com\/blog\/isolation-transformers-understanding-their-purposes-and-functions\/","title":{"rendered":"Isolation Transformers: Understanding Their Purposes and Functions"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"1910\" class=\"elementor elementor-1910\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-6ff4a41 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"6ff4a41\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-08a2c2c\" data-id=\"08a2c2c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-892f534 elementor-widget elementor-widget-text-editor\" data-id=\"892f534\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">In most transformers, voltage adjustment is the main job. Power transformers are built to change voltage levels to appropriate values for distribution and transmission. However, isolation transformers are built for something else. The working of these transformers is very different from how a power or distribution transformer functions. Electric shocks, electrical noise in communication devices, and high frequencies from motors and VFDs are the common problems addressed by an isolation transformer.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-a9e774a elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"a9e774a\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4cae424\" data-id=\"4cae424\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-fd202ab elementor-widget elementor-widget-heading\" data-id=\"fd202ab\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Purpose of Isolation Transformer\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-512c8a9 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"512c8a9\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-302bc1a\" data-id=\"302bc1a\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8f9ae14 elementor-widget elementor-widget-text-editor\" data-id=\"8f9ae14\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400; color: #000000;\">The key purpose of an isolation transformer is to isolate the input power source from the load. This separation is important for several reasons. There could be a fault on the supply side. Even if there is no fault in the direct power source, contacting a live conductor that is fixed to Earth through the neutral conductor gives a dangerous shock to the personnel. Moreover, large equipment can inject electrical noise into the power lines, which can cause the sensitive equipment to malfunction.\u00a0<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-46496de elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"46496de\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-23d0b9e\" data-id=\"23d0b9e\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-02a4547 elementor-widget elementor-widget-heading\" data-id=\"02a4547\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Construction: An Important Aspect of Isolation Transformer<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-d9fccde elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"d9fccde\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-0f4a7a6\" data-id=\"0f4a7a6\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-987f841 elementor-widget elementor-widget-text-editor\" data-id=\"987f841\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Construction of isolation transformers is what makes them different from conventional transformers. The primary and secondary windings share a common magnetic core but are electrically separated. The number of turns in the windings is the same, so the same voltage is transferred. What is not transferred is the current through the windings. Thus, any electrical contact between the load and power source is absent and power is transferred through electromagnetic induction.<\/span><\/p><p><b>What Is Galvanic Isolation<\/b><\/p><p><span style=\"font-weight: 400;\">Galvanic isolation is when the two circuits are separated while allowing power to flow between them. By not allowing the flow of current, it eliminates the risk of fault current flowing, leakages and ground loops.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-0f217ee elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"0f217ee\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-14776a4\" data-id=\"14776a4\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7c4f7da elementor-widget elementor-widget-heading\" data-id=\"7c4f7da\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Various Functions\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-38dfcb7 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"38dfcb7\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-946128e\" data-id=\"946128e\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-b94be48 elementor-widget elementor-widget-text-editor\" data-id=\"b94be48\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Here are the key functions of the isolation transformer:<\/span><\/p><p><b>Fixing Ground Loops<\/b><\/p><p><span style=\"font-weight: 400;\">Isolation transformer separates the direct electrical connection between the source and load, thus eliminating the path for the undesirable currents. The result is better equipment performance and improvements in signal quality.<\/span><\/p><p><b>Creating Neutral Point<\/b><\/p><p><span style=\"font-weight: 400;\">In many electrical installations, the output of an isolation transformer is grounded on purpose to create a new neutral point, thus creating an independently derived electrical system with its own neutral-to-ground connection. This contributes to the proper functioning of protective devices, including circuit breakers and residual current devices.<\/span><\/p><p><b>Blocking Electrical Noise<\/b><\/p><p><span style=\"font-weight: 400;\">Isolation transformer minimizes transfer of common-mode electrical noise from supply to load. With the use of an electrostatic shield, its effectiveness at blocking interference from reaching the equipment is increased.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-37715fd elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"37715fd\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-c5dd21a\" data-id=\"c5dd21a\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7d552ca elementor-widget elementor-widget-heading\" data-id=\"7d552ca\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Conclusion<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-7290c1b elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"7290c1b\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-bcaa494\" data-id=\"bcaa494\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-39af507 elementor-widget elementor-widget-text-editor\" data-id=\"39af507\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400; color: #000000;\">Isolation transformers are a key part of electrical systems, especially where safety, power quality, and reliability are primary concerns. Unlike standard transformers that serve only to change voltage, isolation transformers ensure total electrical separation between the supply and the load. It minimizes the chances of electric shock, reduces electrical noise, solves ground loop problems, and protects delicate devices against disturbances in power. As industries are becoming increasingly reliant on automation, medical equipment, communication systems, and precision devices, the need for effective isolation transformers continues to rise. At Servokon, we produce high-quality isolation transformers that guarantee a high level of electrical insulation, dependable functioning, and long operating life.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>In most transformers, voltage adjustment is the main job. Power transformers are built to change voltage levels to appropriate values for distribution and transmission. However,<\/p>\n","protected":false},"author":1,"featured_media":1911,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-1910","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Isolation Transformers: Understanding Their Purposes and Functions | Servokon<\/title>\n<meta name=\"description\" content=\"Isolation transformers are transformers that physically separate primary and secondary windings in order to prevent undesired noise from being transferred. | Servokon\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.servokon.com\/blog\/isolation-transformers-understanding-their-purposes-and-functions\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Isolation Transformers: Understanding Their Purposes and Functions | Servokon\" \/>\n<meta property=\"og:description\" content=\"Isolation transformers are transformers that physically separate primary and secondary windings in order to prevent undesired noise from being transferred. | Servokon\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.servokon.com\/blog\/isolation-transformers-understanding-their-purposes-and-functions\/\" \/>\n<meta property=\"og:site_name\" content=\"Servokon System Ltd.\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-15T07:27:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-01T07:30:36+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.servokon.com\/blog\/wp-content\/uploads\/2026\/08\/Artboard-2.jpg-4.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"1600\" \/>\n\t<meta property=\"og:image:height\" content=\"1200\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"servo\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"servo\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.servokon.com\\\/blog\\\/isolation-transformers-understanding-their-purposes-and-functions\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.servokon.com\\\/blog\\\/isolation-transformers-understanding-their-purposes-and-functions\\\/\"},\"author\":{\"name\":\"servo\",\"@id\":\"https:\\\/\\\/www.servokon.com\\\/blog\\\/#\\\/schema\\\/person\\\/c228dca4c16f0aa93387c00e48d77f61\"},\"headline\":\"Isolation Transformers: Understanding Their Purposes and Functions\",\"datePublished\":\"2026-07-15T07:27:00+00:00\",\"dateModified\":\"2026-08-01T07:30:36+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.servokon.com\\\/blog\\\/isolation-transformers-understanding-their-purposes-and-functions\\\/\"},\"wordCount\":519,\"image\":{\"@id\":\"https:\\\/\\\/www.servokon.com\\\/blog\\\/isolation-transformers-understanding-their-purposes-and-functions\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.servokon.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/Artboard-2.jpg-4.jpeg\",\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.servokon.com\\\/blog\\\/isolation-transformers-understanding-their-purposes-and-functions\\\/\",\"url\":\"https:\\\/\\\/www.servokon.com\\\/blog\\\/isolation-transformers-understanding-their-purposes-and-functions\\\/\",\"name\":\"Isolation Transformers: Understanding Their Purposes and Functions | Servokon\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.servokon.com\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.servokon.com\\\/blog\\\/isolation-transformers-understanding-their-purposes-and-functions\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.servokon.com\\\/blog\\\/isolation-transformers-understanding-their-purposes-and-functions\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.servokon.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/Artboard-2.jpg-4.jpeg\",\"datePublished\":\"2026-07-15T07:27:00+00:00\",\"dateModified\":\"2026-08-01T07:30:36+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.servokon.com\\\/blog\\\/#\\\/schema\\\/person\\\/c228dca4c16f0aa93387c00e48d77f61\"},\"description\":\"Isolation transformers are transformers that physically separate primary and secondary windings in order to prevent undesired noise from being transferred. | Servokon\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.servokon.com\\\/blog\\\/isolation-transformers-understanding-their-purposes-and-functions\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.servokon.com\\\/blog\\\/isolation-transformers-understanding-their-purposes-and-functions\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.servokon.com\\\/blog\\\/isolation-transformers-understanding-their-purposes-and-functions\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.servokon.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/Artboard-2.jpg-4.jpeg\",\"contentUrl\":\"https:\\\/\\\/www.servokon.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/Artboard-2.jpg-4.jpeg\",\"width\":1600,\"height\":1200,\"caption\":\"Isolation Transformers\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.servokon.com\\\/blog\\\/isolation-transformers-understanding-their-purposes-and-functions\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.servokon.com\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Isolation Transformers: Understanding Their Purposes and Functions\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.servokon.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.servokon.com\\\/blog\\\/\",\"name\":\"Servokon System Ltd.\",\"description\":\"Rakhe Sab Control Mein\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.servokon.com\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.servokon.com\\\/blog\\\/#\\\/schema\\\/person\\\/c228dca4c16f0aa93387c00e48d77f61\",\"name\":\"servo\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d1d64f49a2d92fec591b0ca25003ddeb4208347a13f1b4acf1b635f16f3a3a3d?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d1d64f49a2d92fec591b0ca25003ddeb4208347a13f1b4acf1b635f16f3a3a3d?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d1d64f49a2d92fec591b0ca25003ddeb4208347a13f1b4acf1b635f16f3a3a3d?s=96&d=mm&r=g\",\"caption\":\"servo\"},\"sameAs\":[\"https:\\\/\\\/www.servokon.com\\\/blog\"],\"url\":\"https:\\\/\\\/www.servokon.com\\\/blog\\\/author\\\/servo\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Isolation Transformers: Understanding Their Purposes and Functions | Servokon","description":"Isolation transformers are transformers that physically separate primary and secondary windings in order to prevent undesired noise from being transferred. | Servokon","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.servokon.com\/blog\/isolation-transformers-understanding-their-purposes-and-functions\/","og_locale":"en_US","og_type":"article","og_title":"Isolation Transformers: Understanding Their Purposes and Functions | Servokon","og_description":"Isolation transformers are transformers that physically separate primary and secondary windings in order to prevent undesired noise from being transferred. | Servokon","og_url":"https:\/\/www.servokon.com\/blog\/isolation-transformers-understanding-their-purposes-and-functions\/","og_site_name":"Servokon System Ltd.","article_published_time":"2026-07-15T07:27:00+00:00","article_modified_time":"2026-08-01T07:30:36+00:00","og_image":[{"width":1600,"height":1200,"url":"https:\/\/www.servokon.com\/blog\/wp-content\/uploads\/2026\/08\/Artboard-2.jpg-4.jpeg","type":"image\/jpeg"}],"author":"servo","twitter_card":"summary_large_image","twitter_misc":{"Written by":"servo","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.servokon.com\/blog\/isolation-transformers-understanding-their-purposes-and-functions\/#article","isPartOf":{"@id":"https:\/\/www.servokon.com\/blog\/isolation-transformers-understanding-their-purposes-and-functions\/"},"author":{"name":"servo","@id":"https:\/\/www.servokon.com\/blog\/#\/schema\/person\/c228dca4c16f0aa93387c00e48d77f61"},"headline":"Isolation Transformers: Understanding Their Purposes and Functions","datePublished":"2026-07-15T07:27:00+00:00","dateModified":"2026-08-01T07:30:36+00:00","mainEntityOfPage":{"@id":"https:\/\/www.servokon.com\/blog\/isolation-transformers-understanding-their-purposes-and-functions\/"},"wordCount":519,"image":{"@id":"https:\/\/www.servokon.com\/blog\/isolation-transformers-understanding-their-purposes-and-functions\/#primaryimage"},"thumbnailUrl":"https:\/\/www.servokon.com\/blog\/wp-content\/uploads\/2026\/08\/Artboard-2.jpg-4.jpeg","inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.servokon.com\/blog\/isolation-transformers-understanding-their-purposes-and-functions\/","url":"https:\/\/www.servokon.com\/blog\/isolation-transformers-understanding-their-purposes-and-functions\/","name":"Isolation Transformers: Understanding Their Purposes and Functions | Servokon","isPartOf":{"@id":"https:\/\/www.servokon.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.servokon.com\/blog\/isolation-transformers-understanding-their-purposes-and-functions\/#primaryimage"},"image":{"@id":"https:\/\/www.servokon.com\/blog\/isolation-transformers-understanding-their-purposes-and-functions\/#primaryimage"},"thumbnailUrl":"https:\/\/www.servokon.com\/blog\/wp-content\/uploads\/2026\/08\/Artboard-2.jpg-4.jpeg","datePublished":"2026-07-15T07:27:00+00:00","dateModified":"2026-08-01T07:30:36+00:00","author":{"@id":"https:\/\/www.servokon.com\/blog\/#\/schema\/person\/c228dca4c16f0aa93387c00e48d77f61"},"description":"Isolation transformers are transformers that physically separate primary and secondary windings in order to prevent undesired noise from being transferred. | Servokon","breadcrumb":{"@id":"https:\/\/www.servokon.com\/blog\/isolation-transformers-understanding-their-purposes-and-functions\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.servokon.com\/blog\/isolation-transformers-understanding-their-purposes-and-functions\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.servokon.com\/blog\/isolation-transformers-understanding-their-purposes-and-functions\/#primaryimage","url":"https:\/\/www.servokon.com\/blog\/wp-content\/uploads\/2026\/08\/Artboard-2.jpg-4.jpeg","contentUrl":"https:\/\/www.servokon.com\/blog\/wp-content\/uploads\/2026\/08\/Artboard-2.jpg-4.jpeg","width":1600,"height":1200,"caption":"Isolation Transformers"},{"@type":"BreadcrumbList","@id":"https:\/\/www.servokon.com\/blog\/isolation-transformers-understanding-their-purposes-and-functions\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.servokon.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Isolation Transformers: Understanding Their Purposes and Functions"}]},{"@type":"WebSite","@id":"https:\/\/www.servokon.com\/blog\/#website","url":"https:\/\/www.servokon.com\/blog\/","name":"Servokon System Ltd.","description":"Rakhe Sab Control Mein","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.servokon.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.servokon.com\/blog\/#\/schema\/person\/c228dca4c16f0aa93387c00e48d77f61","name":"servo","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/d1d64f49a2d92fec591b0ca25003ddeb4208347a13f1b4acf1b635f16f3a3a3d?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d1d64f49a2d92fec591b0ca25003ddeb4208347a13f1b4acf1b635f16f3a3a3d?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d1d64f49a2d92fec591b0ca25003ddeb4208347a13f1b4acf1b635f16f3a3a3d?s=96&d=mm&r=g","caption":"servo"},"sameAs":["https:\/\/www.servokon.com\/blog"],"url":"https:\/\/www.servokon.com\/blog\/author\/servo\/"}]}},"_links":{"self":[{"href":"https:\/\/www.servokon.com\/blog\/wp-json\/wp\/v2\/posts\/1910","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.servokon.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.servokon.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.servokon.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.servokon.com\/blog\/wp-json\/wp\/v2\/comments?post=1910"}],"version-history":[{"count":4,"href":"https:\/\/www.servokon.com\/blog\/wp-json\/wp\/v2\/posts\/1910\/revisions"}],"predecessor-version":[{"id":1915,"href":"https:\/\/www.servokon.com\/blog\/wp-json\/wp\/v2\/posts\/1910\/revisions\/1915"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.servokon.com\/blog\/wp-json\/wp\/v2\/media\/1911"}],"wp:attachment":[{"href":"https:\/\/www.servokon.com\/blog\/wp-json\/wp\/v2\/media?parent=1910"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.servokon.com\/blog\/wp-json\/wp\/v2\/categories?post=1910"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.servokon.com\/blog\/wp-json\/wp\/v2\/tags?post=1910"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}